Voltage and Current Signal Conditioning

Signal conditioning unit measures the current based on the shunt resistor and measure the voltage based on the potential divider circuit. The two level amplification helps the user to customize the amplifier gains.

 

Measurement range

  • Voltage: 10 to 1000 Vrms
  • Current: 10 to 100Arms 
  • Type : AC and DC

Channel availability

  • 2 Channel
  • 4 Channel
  • 8 Channel

Applications

  • Motor drives.
  • Frequency Inverters.
  • Uninterruptible Power Supply.

Voltage Signal Conditioning

  • Voltage measurement using potential divider circuit
  • Customizable voltage measurement range from 10V to 1000V
  • Gain: 100
  • Very low gain error and drift (+/- 0.2%)
  • Low Non-linearity and drift (0.01%)
  • Bandwidth: 275kHz
  • High CMTI upto 140kV/ µs
  • Isolation voltage: 5000 Vrms
  • Customizable voltage measurement channel: 2, 4 & 8.

Current Signal Conditioning

 

  • Shunt resistor based current sensing
  • Customizable current range from 10A to 100A
  • Gain: 5
  • Very low gain error & drift (+/- 0.3%)
  • Low Non-linerarity and drift (0.03%)
  • Bandwidth: 310kHz
  • High CMTI upto 140kV/ µs
  • Isolation voltage: 5000 Vrms
  • Customizable current measurement channel : 2, 4 & 8

Difference between Shunt and hall based isolated current sensing.

 

Category Shunt-based Hall-based
Solution  Size Similar Similar
Offset Very Low Medium
Offset drift over temperature Low Medium
Accuracy <0.5% after calibration <2% after calibration
Noise Very Low High
Bandwidth Similar Similar
Latency Similar Similar
Non-linearity Very Low High
Long-term stability Very Low Medium
Cost Similar Similar
Vibration impact Very Low Low
Power dissipation Low Very Low
Customization Flexible Limited
error: Content is protected !!